FKD-U RS C2
Environmental Impact
Production Carbon
4.29
kgCO₂e per 0.8 m2
Declared Unit
0.8 m2
Valid Until
Aug 2026
Third-Party Verified
Yes
Product Details
Rock Mineral Wool Insulation
00 00 00 No Masterformat Code
3.15 kg
EPD International AB
Yaprak Nayir
Yaprak Nayir (Knauf Insulation)
Thermal Insulation products 12/20/2019
2021-08-13
Description
Technical Characteristics: FKD-U RS C2 is in thermal, sound and Parameter Value preventive fire protection in the special application in the area of the reveals of windows Thermal conductivity/ EN 0.035 W/(mK) at 10°C 12667 and doors. Water vapor diffusion 1 resistance (EN 12086) UN CPC code: Thermal Resistance 0.8 m2K/W (ISO 8301) 37990: Non-metallic mineral products (including Reaction to fire (EN 13501-1) A1 mineral wool, expanded mineral materials, Declared density range/ EN 105 kg/m³ (+/-10%) worked mica, articles of mica, non-electrical 1602 Melting point of fibers DIN ≥ 1000°C 4102-17
Lifecycle Breakdown
Lifecycle Stages Covered
Total lifecycle: 5.5 kgCO₂e
Method: EN 15804+A2 · 1.634920635 kgCO₂e/kg